Published July 2014

Development of universal automatic calibration system for oil tanks with complicated configuration

M.A. Aliyev

N.H. Badalova

M.M. Isayev

R.B. Nazarov

K.K. Omarova

Keywords:  
tank
liquid fuel
hydrostatic pressure
differential measurement
calibration table.

Development of problems of automated high-precision calibration system and its software for any geometrical form and sizes oil tanks was considered. To this end, the standard liquid is sequentially discharged to the calibration tank and difference of hydrostatic pressure of liquid columns set up in both tanks is measured simultaneously by one and the same differential pressure meter. For providing high-precision measurement while realizing optimal sampling of hybrid tests on the basis of structural-algorithmic and test methods, a program-technical complex was developed.